Nano Filteration (NF) Plant

  • Home
  • Nano Filteration (NF) Plant

Nano Filteration (NF) Overview

Nanofiltration membranes are a relatively recent development, and offer greater selectivity of ions vs. Reverse osmosis membranes that reject all ion species in a feed stream. This unique characteristic provides flexibility in separation process development that can greatly impact performance and profitability, especially for industrial applications.

Nano Filteration (NF) Principal

Nanofiltration (NF) is very similar to ultra filtration and to reverse osmosis. In all three processes, a hydrostatic pressure is applied to transport a molecular mixture to the surface of a membrane. In general, the solvent and some low molecular weight solutes permeate the membrane while other components are retained.

RO PLANT TECHNICAL & DESIGN FEATURES

Flow :0.2M3/hr to 100M3/hr
Inlet TDS UPTO 42000ppm
Outlet TDS 60 TO 70% REMOVAL FROM INLET PPM
Flux DESIGN 15 lmh to 30 lmh
Temperature 5-45º C
Type of Membranes BW/SW/LF/HS
SDI < 3 at inlet
Control Microprocessor / hmi display with PLC / Scada
Flow Monitoring Rota meter / digital flow meters
Multi grade filter Reduce Turbidity & Total Suspended Solids
Activated carbon filter Remove Colour,odor,toxicity
Pre filters 20 micron & 5 Micron cartridges
High Pressure Pumps Vertical inline SS 304 & 316 ALL WETTED PARTS
NF Skid SS/MSEP
Outlet micro oraganisms NILL (Require UV IN PRODUCT LINE)
Outlet PH 7.0 (+/- 0.5)
Outlet ODOR NILL
Outlet Silica Below Limit
Recovery As per requirement
O&M We maintain plant as per need
Low Pressure Switch To Protect HPP From Dry Run
High Pressure Switch Indicate Membrane Cleaning time
Floaty Auto on/off
Dosing System As per Requirement
Differential pressure transmeter Membrane safety
Online tds meter Monitor tds
Online ph meter Monitor ph
Orp meter Membrane safety
Clean in place(cip) system For Maintenance
Op 485/ data logger To check all parameters
Overload protection RWP & HPP ARE INTERLINK & PROTECTION FROM OVERLOAD

DESIGN

  • AS PER FEED WATER ANALYTICAL PARAMETERS AND CUSTOMER END WATER QUALITY REQUIRENMENT WE DESIGN THE SYSTEM
  • WE DESIGN THE SYSTEM WHICH CAN BE EASY TO OPERATE AND MAINTAIN.
  • USING VARIOUS TECHNOLOGIES WE PROVIDE SUSTAINABLE DESIGN.
  • WE ARE USING DIFFERENT TYPES OF MEMBRANES AND ITS MAKES AND DIFFERENT TYPE OF PUMPS FOR COST EFFECTIVE SOLUTION
  • WE ARE USING ACCURATE PRE & POST RO TREATMENT TO ACHIEVE REQUIRE PARAMETERS.
  • DEEP ANALYSIS , ACCURATE DESIGN , AND SUCCESSFUL O&M
  • WE BELIEVE IN THE CONCEPT CALLED SUCCESS BY DESIGN. THIS MEANS, THATRECURRING SUCCESS CANNOT TAKE PLACE BY CHANCE OR BY ACCIDENT. INSTEAD, IT HAS TO BE CRAFTED,IT HAS TO BE PLANNED.
  • WE ARE SUCCESS IN CLEAN WATER AS WELL AS WASTE WATER DESIGN
  • WE HAVE ACHIEVED 100% RESULTS WHICH WE HAVE COMMITED TO CLIENT.IN CLEAN WATER AND WASTE WATER DESIGN

Silent features

  • CUSTOMIZE programmable controls as per requirement.
  • ALL COMPONENTS USE WITH ITS TEST CERTIFICATE ONLY
  • PLUG AND PLAY ENGINEERED PLANT For Quick Installation
  • Inbuilt Clean-in-place connections For Easy Maintanance.
  • Utilize Minimum footprint but without compromising it's o&m space.
  • provide each project's user manual with Components Data sheet,Test Certificates,Daily Operation And Maintanance Logsheet.
  • Quick Approval Systems Which keeps project moving fast
  • Easy to install and Accurate operation & maintainance.
  • Produces high quality Neutral Water
  • Variety of cost effective standard Components.